LED display planning

How to Estimate LED Video Wall Power Consumption

November 28, 2026LANWEILED

To estimate an LED video wall’s power consumption, multiply its cabinet area by the supplier’s power rating in watts per square metre (W/m²). Calculate both figures on the spec sheet. Use maximum power when discussing the electrical load with the installer, and average power as a starting point for the operating budget.

Check what the power rating includes

  • W/m². Multiply by the total face area of the cabinets in square metres. Use the actual cabinet grid from the drawing. If you have only the opening dimensions, start with the cabinet layout calculation.
  • Watts per cabinet. Multiply by the cabinet count. If the layout mixes cabinet models or sizes, calculate each group separately and add the results.
  • Average or typical power. Ask what brightness, test content and operating settings the supplier used. Compare quotes using the same assumptions where possible.
Technician working inside an open indoor LED cabinet
Service access inside an indoor LED cabinet. Ask for the electrical data and connection drawing for the exact cabinet in your quotation.

Example. A 30-cabinet indoor LED wall

Six columns by five rows of 640 × 480 mm cabinets give a 3.84 × 2.40 m wall, about 12.6 × 7.9 ft. The cabinet face area is 9.216 m². The fixed indoor cabinet specifications list 500 W/m² maximum and 140 W/m² average for the reference P1.25 cabinet. These values come from page 9 of the supplied 2026 company-group catalog.

  • Maximum cabinet load. 9.216 m² × 500 W/m² = 4,608 W, or about 4.61 kW.
  • Average cabinet load at the catalog rating. 9.216 m² × 140 W/m² = 1,290 W after rounding, or about 1.29 kW.
  • Estimated energy for 10 operating hours. At that average load, the cabinets would use about 12.9 kWh. Multiply the estimated kWh by your energy rate per kWh to estimate the energy charge.

This example covers the display cabinets. For the project estimate, confirm which controllers and other equipment are supplied separately and add their loads where applicable. For an existing wall, metered usage during representative playback gives a better basis for the operating budget.

Ask for these details before approving the quote

  • Maximum and average power for the exact model and cabinet count, with the test conditions and the equipment included in each figure.
  • Input voltage, rated input current, startup current and the supplier’s connection plan for the selected cabinets.
  • Ventilation and heat load data for the planned brightness and daily running hours, including any separate equipment rack.

Share the cabinet schedule, connection plan and measured site conditions with the electrical installer for final circuit and protection design. If you are budgeting a fixed indoor wall, send the target size, planned brightness and daily operating hours to request an indoor LED wall quote.

PROJECT INQUIRY

Tell Us About Your LED Display Project

Share the application, approximate screen size, installation location and schedule for a quotation review.

Add name, destination, product or a file (optional)

We use these details to review and respond to your inquiry.

See how inquiry details are handled in our Privacy Policy.