Quick answer: LED floor tiles and roll-up LED carpet are different product formats. Start with the venue, floor plan, expected use and installation method. Then compare model-specific dimensions, resolution, surface protection, loading and interaction requirements. A shared pixel-pitch label does not mean the two formats can be substituted.

What is the practical difference?
A floor-tile system is planned around cabinets assembled into the required footprint. The roll-up carpet catalog instead describes narrow modules joined into a flexible format. This changes the questions to ask about transport, laying the display, edge treatment, service access and storage. The final installation method still depends on the selected model and site design.
For example, the supplied 2026 floor-tile catalog lists a 500 × 1000 mm cabinet for its P2.5 and P3.91 references. The separate roll-up carpet catalog lists a 500 × 62.5 × 17 mm module for its P1.56 and P3.91 references. The module thickness is a component dimension, not a promise about the finished floor height.
Compare the right reference data
These selected rows show why a proposal should identify the product series as well as pixel pitch. Cabinet resolution and module resolution describe different physical units, so their pixel counts should not be compared as if they were equal screen sizes.
| Format and catalog model | Catalog unit size | Unit resolution |
|---|---|---|
| Floor tile P2.5 | 500 × 1000 mm cabinet | 200 × 400 px per cabinet |
| Floor tile P3.91 | 500 × 1000 mm cabinet | 128 × 256 px per cabinet |
| Roll-up carpet P1.56 | 500 × 62.5 × 17 mm module | 320 × 40 px per module |
| Roll-up carpet P3.91 | 500 × 62.5 × 17 mm module | 128 × 16 px per module |
Sources: MVP LED 2026 Digital Catalog, PDF pp. 19–20, for the interactive floor-tile cabinet rows; supplied Roll-Up LED Carpet catalog (卷帘英文), PDF p. 33, for the roll-up module rows. These are group catalog references, not a single combined product specification. The LED floor and roll-up product page lists more model references and their source notes. Confirm the current data sheet for the exact quoted configuration.
Five decisions to make before requesting a quotation
1. Define the use area and traffic
Mark the display footprint on a floor plan. Identify entrances, walkways, places where people may stop, and whether equipment such as carts or display stands will cross the area. Provide the expected usage pattern so the proposed surface and supporting structure can be reviewed. Do not infer a load rating from a catalog photo or pixel pitch.
2. Explain the venue conditions
Share whether the location is indoors, sheltered or exposed; the floor level and finish; available power; and any restrictions on fixing, cable routes or raised edges. Ask for the protection scope of the selected assembled system where moisture, cleaning or spill exposure matters. A rating for one component should not be applied to the whole installation without confirmation.
3. Specify the desired interaction
Describe what visitors should see when they step onto the display. Static playback, timed effects and step-responsive content are different requirements. If step response is needed, confirm the sensing method, controller, content workflow and test procedure for the chosen model. The word “interactive” in a series name does not by itself define the supplied sensor package.
4. Plan installation and removal
Tell the supplier the load-in route, access hours, available crew and expected reuse schedule. For tiles, request the cabinet layout and edge details. For a roll-up format, request model-specific handling, rolling, connector and storage instructions. Allow time to check the full assembled area, including seams and playback, before visitors enter.
5. Build content for the actual canvas
Share the planned screen dimensions and content types before finalizing graphics. Ask for the resulting pixel canvas and orientation of the assembled layout. A floor display is viewed while people move across it, so review text size, visual pacing and any interactive zones in a site mock-up or rehearsal.
Questions buyers often ask
Can a P3.91 roll-up carpet replace a P3.91 floor tile?
Do not assume so. The catalog rows above have the same nominal pitch but different physical units and resolutions. Review loading, surface, handling and installation for the proposed model and venue.
Does a catalog dimension give the final installed height?
No. A listed cabinet or module dimension describes that component. The finished level also depends on the support, edging, cables and floor preparation shown in the project drawing.
What should be included in the first project brief?
Send a dimensioned floor plan, venue photos, indoor or outdoor conditions, expected foot and equipment traffic, interaction goals, event dates, destination and installation restrictions. The exhibition LED display guide and LED display buyer guide cover adjacent planning questions.
Share your floor plan and application details for a project review.